matykiewicz.com matykiewicz.com matykiewicz.com


See also:
 LHPEw-10/2-B-S pull-wire switch
 Lifeline 4 pull-wire switch


SNS11/SNS12 Pull-wire Switch


Functions

Pull-wire switches make quick emergency stopping of conveyor belts or other sizeable devices possible from any place. Pulling a wire causes emergency device’s switching off. It assures work safety near a conveyor belt according to the harmonized EU norms:

EN 1050:1999 “Safety of machinery. Principles of risk assessment."
EN 954-1:2001 „Safety of machinery, Safety-related parts of control systems "
EN 418: "Safety of machinery. Emergency stop equipment, functional aspects ”

Click on this link to get to know more about current norms.

Application

Pull-wire switches are required where people have an access to conveyor belts According to safety norms’ restrictions, the possibility of stopping belt from every place along its length must be secured. In the case of a belt more than a couple meters long, STOP switch near its drive does not fulfill these criteria.

Description

SNS1x pull-wire switches are designed for one-side assembly. Wire’s length should not exceed 25 m. According to PN-EN 60497 and PN-EN 418, the contact (stopping) takes place both in case of pulling a wire and its breaking or loosening. After the activation, the mechanical blockade of the switch takes place. The only possible is manually unblocking, directly on a switch. The switch’ condition could be monitored directly trough the window with the special indicator (normal operation/the wire has been pulled, wire is broken).

The casing is made from zinc-plated steel with the IP 66 protection.

Depending on your needs, we provide you with SNS11 version with one NO contact and one NC contact or with the SNS12 version with two NC contacts.

The casing is equipped with three PG13,5 cable outlets. Two of them are closed with plugs with the proper level of protection; one is equipped with screw closing.

Technical parameters

Fulfilling norms: EN 60947, EN 60954, EN 292, UVV-VBG10, PN-EN 418
Switching path: 4 mm
Wire’s length: up to 25 m
Cable outlets: 3 x Pg 13,5
Casing protection: IP 66
Casing material: Zn A14 Cu zinc-plated steel
Contacts: 1 NO and 1 NC with the forced spread (SNS11)
or 2 NC (SNS 12), silver-plated
Leads’ cross section: 1,5 mm2
Weight: 0,7 kg
Load: AC 15: 24V 10A, 125V 10A, 230V 6A, 400V 4A
DC13: 24V 10A, 48V 4A, 120V 1A, 250V 0,4A
Installation: two holes for M5 screws, location of the switch is arbitrary
Motility: mechanical 1.000.000 activations
electrical 500.000 activations with 250V AC 6A cosphi=1


SNS11/SNS12 switch dimensions

wyłącznik linkowy SNS12

Last update: