 LHPEw-10/2-BSL(R)-S pull-wire switch
 LHPE-10/1-L belt misalignment sensor
 Lifeline 4 pull-wire switch


LHPE(w)-10/x-R Lever Limit Switch



Functions

Lever limit switch serves for signaling changes of device location or its part to prevent from damaging a device because of its dislocation beyond its proper location.

Depending on the way of the contacts connection to the control system, warning signaling or stopping of device drive are activated.

Application

Mechanical protection of devices in heavy industry, also in the condition of heavy dusting, humidity, etc.



Description

The switch is equipped with lever with a roller which rotates in the moment of the contact with a part that changes its proper place. .

Apart from a lever, the sensor is equipped with the assemblage legs, possible (version with a blockade) lever of reset and two outputs for M25 cable outlets. Inside, there is a starting mechanism and specified number of microcontacts (1 to 4 – their number is defined by the switch’ symbol – figure behind a slash).

The characteristic feature of the switches of LHPE series is very high durability, which, thanks to IP 67 protection, enables to use LHPE switches in the typical industrial, harsh conditions.

Technical parameters

Operation angle: 25°
Outputs: M25 x 1,5
Casing: IP 67
Protection class: 2
Contacts: self-cleaning, also for low currents
Number of contacts: 1NC+1NO or 2NC+2NO or more if needed
Load: 400V AC 6A / 230V AC 8A / 24V DC 10A / 80V DC 3A
Casing’s material: polyester hardened with fiberglass (cast ion optionally)
Color: yellow RAL 1004 or other on the special order
Weight: 2,0 kg
Installation: two holes for M10 screws
Ambient temperature: -40°C to +85°C


Lever limit switches dimension